TJA1052IT-5Y_ What to Do When the Transceiver Gets Stuck in Bus-Off Mode

TJA1052IT-5Y: What to Do When the transceiver Gets Stuck in Bus-Off Mode

Troubleshooting " TJA1052IT/5Y : What to Do When the Transceiver Gets Stuck in Bus-Off Mode"

When using the TJA1052IT/5Y CAN transceiver, one of the issues that may arise is the transceiver entering a Bus-Off mode. This mode typically occurs due to a fault in the CAN network, where the transceiver detects an excessive number of errors. In this guide, we’ll break down why this happens, what causes it, and step-by-step solutions to fix it.

1. Understanding Bus-Off Mode

Bus-Off mode is a protective state in which a CAN transceiver like the TJA1052IT/5Y disables itself from transmitting messages on the CAN bus. This occurs to prevent faulty devices from affecting the Communication on the network.

2. Common Causes of Bus-Off Mode

The TJA1052IT/5Y transceiver may enter Bus-Off mode due to several reasons:

Excessive Transmission Errors: If the transceiver encounters too many transmission errors (e.g., bit errors, CRC errors, etc.), it will go into Bus-Off mode to prevent further network disruptions. Bus Contention: When multiple nodes try to send messages at the same time, bus contention can occur, causing errors that lead the transceiver to enter Bus-Off mode. Faulty Termination: Incorrect termination of the CAN bus (either missing or wrong value of termination resistors) can cause reflections and communication errors, resulting in the transceiver entering Bus-Off mode. Signal Integrity Problems: Issues like loose connections, damaged wiring, or electromagnetic interference can cause signal distortion on the CAN bus, which can lead to transmission errors. Incorrect Configuration: The TJA1052IT/5Y may be incorrectly configured, leading to communication errors. This includes wrong baud rate settings or improper Timing .

3. How to Resolve the Bus-Off Mode Issue

To resolve a Bus-Off condition, follow these steps:

Step 1: Identify the Cause Check the Network for Faults: Verify the CAN network for any physical damage (loose connections, poor grounding, etc.), and ensure proper termination (typically 120Ω at both ends of the bus). Examine the Communication: Use a CAN analyzer tool to check for excessive errors in transmission. Look for issues like bit errors, CRC errors, or acknowledgment errors. Step 2: Diagnose the Faulty Node If the network is free of issues, check the node that is stuck in Bus-Off mode. A faulty node might be transmitting invalid messages, causing errors. Power Cycle the Node: Power off the transceiver and then power it back on. This action resets the Bus-Off state. If it’s still stuck in Bus-Off mode, further steps may be required. Step 3: Bus-Off Recovery Enable Bus-Off Recovery Mode: The TJA1052IT/5Y has an automatic recovery feature. If the transceiver has been in Bus-Off for long enough, it should automatically recover after 128 occurrences of Bus-Error (the default setting). Ensure this feature is enabled in the configuration. Step 4: Check for Timing Issues Ensure that the baud rate settings are correct and match the configuration of the rest of the CAN network. A mismatch here can lead to timing errors that cause the transceiver to enter Bus-Off mode. Step 5: Reconfigure the CAN Transceiver If the automatic recovery does not resolve the issue, try manually resetting the transceiver’s error counters using the error counter reset pin or command, which is part of the TJA1052IT/5Y functionality. Step 6: Verify the Network Topology Confirm the proper configuration of the CAN network. Make sure that the bus length, node count, and termination resistors are within acceptable limits. A poorly designed network can contribute to errors that lead to the Bus-Off state. Step 7: Isolate the Faulty Node If none of the above solutions work, the issue might be with the particular node stuck in Bus-Off mode. Disconnect it from the CAN network and check if the other devices communicate correctly. If they do, the faulty node needs to be repaired or replaced.

4. Conclusion

To prevent the TJA1052IT/5Y from getting stuck in Bus-Off mode, it's crucial to ensure proper network design, correct termination, and clean signal integrity. Diagnosing and resolving the issue involves a step-by-step process, including checking the physical network, reviewing configuration settings, and making use of the transceiver's built-in error recovery mechanisms.

By systematically isolating the problem, you can restore the transceiver to normal operation and maintain stable communication on the CAN bus.